[DIY] Re: Running Electricity to shed

 

With a 60 amp breaker in the house, you need #6 minimum.  As you stated, you are running PVC conduit.  I would use 1" and THHN single conductor wire instead of romex.  You can either run 3 wires + a #10 ground wire or just 3- #6"s and put a ground rod @ the shed connected to the neutral bar in the panel.  If you run a seperate ground, isolate the grounds from the neutral.  Also connect any metal water pipes to the ground as well.

__._,_.___

Posted by: dcwired@att.net
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (8)
Please send decorating questions to Interior Motives List - to subscribe send an email to: Interior_Motives-subscribe@yahoogroups.com

.

__,_._,___

Re: [DIY] Re: Stripping a 15 pane door

 

Thanks Jeff. I completely forgot about the heat gun.
Wonder where I put it? lol





Joyce aka Mom aka Nana


On Fri, Oct 2, 2015 at 1:53 PM, jeffinvero@hotmail.com [DoIt_Yourself] <DoIt_Yourself@yahoogroups.com> wrote:
 

Try a heat gun.  It will boil up the finish to scrap off and then SAND YOUR LITTLE HEART OUY.  jeff


__._,_.___

Posted by: Joyce O <theoldhen@gmail.com>
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (3)
Please send decorating questions to Interior Motives List - to subscribe send an email to: Interior_Motives-subscribe@yahoogroups.com

.