Freezing can be caused by 1) dirty filter (low airflow on inside cooling coil); 2)  thermostat set too low at night (below 70'f), 3) blower fan motor running slow/ not starting properly, 4) several other technical issues  ACTIONS: 1) Change FILTER; 2) Set thermostat HEAT/OFF/ COOL switch to OFF (or turn setting up to 85); turn Fan AUTO/ RUN (On) to RUN and allow to run for 1-2 hrs to defrost.  After timeout, reset to COOL and 72-78-deg. and you may/ may not have trouble.  If you do, call serviceman.
  
             
             
    Terry    
    thenne1713@aol.com
    
__._,_.___
                                   Posted by: Terry <thenne1713@aol.com>
| Reply via web post | • | Reply to sender | • | Reply to group | • | Start a New Topic | • | Messages in this topic (8) | 
                    Please send decorating questions to Interior Motives List - to subscribe send an email to: Interior_Motives-subscribe@yahoogroups.com                 
                       .